H100+ 480VAC HVAC / Pump Drives
Drive View – PC Based Software for Commissioning and Monitoring software.
Optional Cards
- Ethernet/IP
- Modbus – TCP
LS Electric LSLV0037H100-4COFN(PLUS)
New, 460VAC, 3 Phase, 3 - 5 HP
CONFIGURATION
Integrated EMC filter - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 3hp / 2.2 kw - 5.5a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 5hp / 3.7 kw - 8.0a
Dimensions: 6.3"W x 9.13"H x 7.13"D
2 Year Warranty
LS Electric LSLV0055H100-4COFN(PLUS)
New, 460VAC, 3 Phase, 5 - 7.5 HP
CONFIGURATION
Integrated EMC filter - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 5hp / 3.7 kw - 8.0a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps7.5hp / 5.5 kw - 12.0a
Dimensions: 6.3"W x 9.13"H x 7.13"D
2 Year Warranty
LS Electric LSLV0075H100-4COFN(PLUS)
New, 460VAC, 3 Phase, 7.5 - 10 HP
CONFIGURATION
Integrated EMC filter - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 7.5hp / 5.5 kw - 12a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 10hp / 7.5 kw - 16a
Dimensions: 6.3"W x 9.13"H x 7.13"D
2 Year Warranty
LS Electric LSLV0110H100-4COFN(PLUS)
New, 460VAC, 3 Phase, 10 - 15 HP
CONFIGURATION
Integrated EMC filter - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 10hp / 7.5 kw - 15a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps15hp / 11 kw - 24a
Dimensions: 6.3"W x 9.13"H x 7.13"D
2 Year Warranty
LS Electric LSLV0150H100-4COFN(PLUS)
New, 460VAC, 3 Phase, 15 - 20 HP
CONFIGURATION
Integrated EMC filter - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 15hp / 11 kw - 22a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps20hp / 15 kw - 30a
Dimensions: 7.09"W x 11.42"H x 8.08"D
2 Year Warranty
LS Electric LSLV0185H100-4COFN(PLUS)
New, 460VAC, 3 Phase, 20 - 25 HP
CONFIGURATION
Integrated EMC filter - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 20hp / 15 kw - 28a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps25hp / 18.5 kw - 38a
Dimensions: 7.09"W x 11.42"H x 8.08"D
2 Year Warranty
LS Electric LSLV0220H100-4COFD(PLUS)
Sold out
New, 460VAC, 3 Phase, 25 - 30 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 25hp / 18.5 kw - 35a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps30hp / 22 kw - 45a
Dimensions: 8.66"W x 13.78"H x 8.79"D
2 Year Warranty
LS Electric LSLV0300H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 30 - 40 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 30hp / 22 kw - 41a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps40hp / 30 kw - 61a
Dimensions: 8.66"W x 13.78"H x 8.79"D
2 Year Warranty
LS Electric LSLV0370H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 40 - 50 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 40hp / 30 kw - 55a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 50hp / 37 kw - 75a
Dimensions: 10.83"W x 17.72"H x 11.18"D
2 Year Warranty
LS Electric LSLV0450H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 50 - 60 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 50hp / 37 kw - 67a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 60hp / 45 kw - 91a
Dimensions: 12.80"W x 20.08"H x 11.18"D
2 Year Warranty
LS Electric LSLV0550H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 60 - 75 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 60hp / 45 kw - 81a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 75hp / 55 kw - 107a
Dimensions: 12.80"W x 20.08"H x 11.18"D
2 Year Warranty
LS Electric LSLV0750H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 75 - 100 HP
CONFIGURATION
Integrated EMC filter - DC Rector - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 75hp / 55 kw - 106a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 100hp / 75 kw - 142a
Dimensions: 12.80"W x 21.67"H x 12.8"D
2 Year Warranty
LS Electric LSLV0900H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 100 - 125 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 100hp / 75 kw - 136a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 125hp / 90 kw - 169a
Dimensions: 12.80"W x 21.67"H x 11.18"D
2 Year Warranty
LS Electric LSLV1100H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 125 - 150 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 125hp / 90 kw - 169a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 150hp / 110 kw - 223a
Dimensions: 11.81"W x 27.80"H x 15.20"D
2 Year Warranty
LS Electric LSLV1320H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 150 - 200 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 150hp / 110kw - 195a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 200hp / 132 kw-264a
Dimensions: 11.81"W x 27.80"H x 15.20"D
2 Year Warranty
LS Electric LSLV1600H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 200 - 250 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 200hp / 132kw-255a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 250hp / 160 kw-325a
Dimensions: 14.96"W x 27.76"H x 15.59"D
1 Year Warranty
LS Electric LSLV1850H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 250 - 300 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP20 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 250hp / 160kw-303a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 300hp / 185 kw-370a
Dimensions: 14.96"W x 27.76"H x 15.59"D
2 Year Warranty
LS Electric LSLV2500H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 300 - 400 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP00 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 300hp / 220kw-375a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 400hp / 250 kw-481a
Dimensions: 16.77"W x 36.34"H x 17.32"D
2 Year Warranty
LS Electric LSLV3150H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 400 - 500 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP00 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 400hp / 250kw-478a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 500hp / 315 kw-613a
Dimensions: 23.62"W x 39.37"H x 19.69"D
2 Year Warranty
LS Electric LSLV3550H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 450 - 550 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP00 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 450hp / 315kw-541a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 550hp / 355 kw-683a
Dimensions: 23.62"W x 39.37"H x 19.69"D
2 Year Warranty
LS Electric LSLV4000H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 500 - 650 HP
CONFIGURATION
Integrated EMC filter - DC Reactor - IP00 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 500hp / 355kw-591a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 650hp / 400 kw-770a
Dimensions: 23.62"W x 39.37"H x 19.69"D
2 Year Warranty
LS Electric LSLV5000H100-4COFD(PLUS)
New, 460VAC, 3 Phase, 650 - 800 HP
CONFIGURATION
Integrated EMC filter - DC Reactor- IP00 - Built in BACnet MS/TP
Constant Torque: O.L.= HD 150%-60s Kw @ 400vac HP @ 460vac - Amps 650hp / 400kw-740a
Variable Torque: O.L.= LD 110%-60s Kw @ 400vac HP @ 460vac - Amps 800hp / 500 kw-962a
Dimensions: 30.55"W x 41.50"H x 19.67"D
2 Year Warranty